Oferta!

Controlador de carga MPPT EPERVER XTRA4210N-XDS2

Original price was: R$ 1.200,00.Current price is: R$ 999,00.

Qualquer duvidas fale conosco via whatsapp

Pagamento via transferência ou Pix 7% desconto.

Antes de comprar informar o município de entrega para calculo correto de impostos.

Descrição

Descrição

XTRA 2206N, XTRA 1210N, XTRA 2210N, XTRA 4210N, XTRA  3210N, XTRA  3215N,
XTRA 4215N, XTRA 3415N, XTRA 4415N
Electrical
12/24VDC 1 Auto
System Nominal Voltage
12/24/36/48VDC 1 Auto
Rated Charge Current 10A 20A 10A 20A 30A 40A 30A 40A 30A 40A
Rated Discharge Current 10A

20A 10A 20A 30A 40A 30A 40A 30A 40A
8~32V
Battery Voltage Range
60V 2
46V 3
Max. PV Open Circuit Voltage
MPPT Voltage Range
Max. PV Input Power (W/V)
(Battery voltage +2V)~36V
100V 2
92V 3 150V 2
138V 3
(Battery voltage +2V)~72V (Battery voltage +2V)~108V
130/12 260/12 130/12 260/12 390/12 520/12 390/12 520/12
260/24 520/24 260/24 520/24 780/24 1040/24 780/24 1040/24
Equalization Voltage 4
Boost Voltage
8~68V
Gel:14.2V; Sealed:14.4V; Flooded:14.6V; User: 17-9V
Float Voltage 4 Gel /Sealed /Flooded: 13.8V; User: 17~9V
Low Voltage Reconnect Voltage 4 Gel /Sealed /Flooded: 12.6V; User: 17~9V
Low Voltage Disconnect Voltage 4 Gel /Sealed /Flooded: 11.1V; User: 17~9V
Discharge circuit voltage drop
Temperature Compensate
coefficient 5
Grounding
RS485 interface
LCD backlight time
≤14mA(12V)
≤15mA(24V)
≤35mA(12V)
≤22mA(24V)
≤0.23V
-3mV/ 0 C/2V (Default)
Common negative grounding
5VDC/200mA (RJ45)
60S (Default)
Environmental
Working environment temperature 6
(full rated power with no derating)
Storage temp. range
Relative humidity
520/12
1040/24
1560/36
2080/48
Sealed: 14.6V; Flooded: 14.8V; User: 17~9V
4
Self-consumption
390/12
780/24
1170/36
1560/48
-25°C~+50°C(LCD);-30°C~+50°C(No LCD)
-20 0 C~+70 0 C
≤ 95% , N.C.
Enclosure IP33 7
Pollution degree PD2
www.epsolarpv.com
≤35mA(12V) ≤16mA(36V)
≤22mA(24V) ≤16mA(48V)Item
XTRA
1206N
XTRA
2206N
XTRA
1210N
XTRA
2210N
XTRA
3210N
XTRA
4210N
XTRA
3215N
XTRA
4215N
XTRA
3415N
XTRA
4415N
Certification
EN/IEC62109-1
Safety
EMC(Emission immunity) EN61000-6-3/EN61000-6-1
FCC 47 CFR Part 15, Subpart B
Performance &function
IEC62509
IEC62321-3-1
ROHS
Item
XTRA 1206N
XTRA 1210N
XTRA 2206N
XTRA 2210N
XTRA 3210N XTRA 4210N
XTRA 3215N XTRA 4215N
XTRA 3415N XTRA 4415N
Mechanical
Dimension(mm)
Mounting dimension(mm)
175×143×48 217×158×56.5 230×165×63 255×185×67.8 255×187×75.7 255×189×83.2
120×134 160×149 173×156 200×176 200×178 200×180
Mounting hole size
Φ5mm
Terminal 12AWG(4mm2) 6AWG(16mm2) 6AWG(16mm2) 6AWG(16mm2) 6AWG(16mm2) 6AWG(16mm2)
Recommended cable 12AWG(4mm2) 10AWG(6mm2) 8AWG(10mm2) 6AWG(16mm2) 8AWG(16mm2) 6AWG(16mm2)
0.57kg 0.96kg 1.31kg 1.70kg 2.07kg 2.47kg
Weight
1 When selecting lithium battery type, the system voltage can’t be identified automatically
2 At minimum operating environment temperature
3 At 25°C environment temperature
4 When selecting lithium battery type, the temperature compensation coefficient is 0, and can’t be set
5 The parameters are 12V system at 25 oC, ×2 in 24V system at 25 oC, ×4 in 48V system at 25 oC
6 The controller can full load working in the working environment temp. range, When the
internaltemperature reach to 81°C, the reducing charging power mode is turned on
7 3 – protection against solid objects: protected against solids objects over 2.5mm
2 – protection against liquids: protected against direct sprays up to 15 ° from the vertical

Avaliações

Não há avaliações ainda.

Apenas clientes logados que compraram este produto podem deixar uma avaliação.